{"id":3083,"date":"2026-05-14T00:30:00","date_gmt":"2026-05-14T00:30:00","guid":{"rendered":"https:\/\/glground.co\/?p=3083"},"modified":"2026-05-07T17:03:10","modified_gmt":"2026-05-07T17:03:10","slug":"que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra","status":"publish","type":"post","link":"https:\/\/glground.co\/en\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/","title":{"rendered":"Qu\u00e9 exige el RETIE vigente para dise\u00f1o de sistemas de puesta a tierra"},"content":{"rendered":"<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"607\" src=\"https:\/\/glground.co\/wp-content\/uploads\/2026\/05\/Gemini_Generated_Image_k5a77lk5a77lk5a7-1024x607.webp\" alt=\"qu\u00e9 exige el retie vigente para el dise\u00f1o de puestas a tierra 2026\" class=\"wp-image-3084\" srcset=\"https:\/\/glground.co\/wp-content\/uploads\/2026\/05\/Gemini_Generated_Image_k5a77lk5a77lk5a7-1024x607.webp 1024w, https:\/\/glground.co\/wp-content\/uploads\/2026\/05\/Gemini_Generated_Image_k5a77lk5a77lk5a7-300x178.webp 300w, https:\/\/glground.co\/wp-content\/uploads\/2026\/05\/Gemini_Generated_Image_k5a77lk5a77lk5a7-768x455.webp 768w, https:\/\/glground.co\/wp-content\/uploads\/2026\/05\/Gemini_Generated_Image_k5a77lk5a77lk5a7-18x12.webp 18w, https:\/\/glground.co\/wp-content\/uploads\/2026\/05\/Gemini_Generated_Image_k5a77lk5a77lk5a7.webp 1295w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>El dise\u00f1o de un sistema de <strong>puesta a tierra<\/strong> en Colombia no es una decisi\u00f3n t\u00e9cnica aislada, es una <strong>obligaci\u00f3n normativa<\/strong>. El <strong>RETIE vigente<\/strong> establece requisitos claros que buscan algo muy espec\u00edfico: proteger la vida humana y garantizar el correcto funcionamiento de las instalaciones el\u00e9ctricas.Uno de los errores m\u00e1s comunes es pensar que cumplir con el RETIE es lograr un valor bajo de resistencia. La realidad es otra: el reglamento exige un <strong>dise\u00f1o integral<\/strong>, basado en condiciones reales del terreno, comportamiento de la corriente y control de riesgos el\u00e9ctricos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">El RETIE no permite dise\u00f1ar \u201ca ojo\u201d<\/h2>\n\n\n\n<p>El <strong>RETIE vigente<\/strong> es expl\u00edcito: no se puede instalar un sistema de <strong>puesta a tierra<\/strong> sin un estudio t\u00e9cnico previo.<\/p>\n\n\n\n<p>El dise\u00f1o debe partir de mediciones reales del suelo, especialmente la resistividad, y no de valores asumidos o referencias gen\u00e9ricas. Esto significa que cada proyecto debe analizarse de forma individual, considerando su contexto el\u00e9ctrico y f\u00edsico.<\/p>\n\n\n\n<p>En otras palabras, copiar soluciones o usar \u201crecetas\u201d est\u00e1ndar no cumple con la norma.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Requisito clave: an\u00e1lisis del suelo<\/h2>\n\n\n\n<p>Todo dise\u00f1o inicia con el estudio del terreno. El RETIE exige identificar las caracter\u00edsticas del suelo antes de definir cualquier sistema.<\/p>\n\n\n\n<p>Esto incluye:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Resistividad del terreno<\/li>\n\n\n\n<li>Variaciones por humedad<\/li>\n\n\n\n<li>Composici\u00f3n del suelo<\/li>\n<\/ul>\n\n\n\n<p>Este an\u00e1lisis es la base para dimensionar correctamente el sistema y evitar fallas futuras. Sin este paso, el dise\u00f1o simplemente no es v\u00e1lido desde el punto de vista normativo.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Corriente de falla y tiempo de despeje<\/h2>\n\n\n\n<p>El RETIE no se enfoca solo en el terreno, tambi\u00e9n exige analizar el comportamiento el\u00e9ctrico del sistema.<\/p>\n\n\n\n<p>Para dise\u00f1ar correctamente una <strong>puesta a tierra<\/strong>, se debe determinar:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>La corriente m\u00e1xima de falla a tierra<\/li>\n\n\n\n<li>El tiempo de operaci\u00f3n de las protecciones<\/li>\n<\/ul>\n\n\n\n<p>Estos dos factores son cr\u00edticos porque definen el nivel de riesgo real en una instalaci\u00f3n. El sistema debe ser capaz de disipar esa corriente sin generar condiciones peligrosas para las personas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Control de tensiones de paso y contacto<\/h2>\n\n\n\n<p>Aqu\u00ed est\u00e1 uno de los puntos m\u00e1s importantes (y m\u00e1s ignorados): el RETIE prioriza el control de las tensiones de paso y contacto por encima de cualquier valor de resistencia.<\/p>\n\n\n\n<p>El dise\u00f1o debe garantizar que estas tensiones no superen los l\u00edmites que el cuerpo humano puede soportar. Esto implica que incluso un sistema con baja <strong>resistencia de puesta a tierra<\/strong> puede ser inseguro si no controla correctamente estas variables.<\/p>\n\n\n\n<p>Adem\u00e1s, el reglamento exige evaluar tensiones transferidas y ajustar el dise\u00f1o hasta cumplir condiciones seguras.<\/p>\n\n\n\n<p>Este es el verdadero enfoque del RETIE: seguridad real, no solo cumplimiento num\u00e9rico.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Requisitos sobre materiales y conductores<\/h2>\n\n\n\n<p>El <strong>RETIE vigente<\/strong> tambi\u00e9n establece condiciones estrictas sobre los elementos del sistema de <strong>puesta a tierra<\/strong>.<\/p>\n\n\n\n<p>Los conductores deben:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ser continuos, sin interrupciones<\/li>\n\n\n\n<li>Estar dimensionados seg\u00fan la corriente de falla<\/li>\n\n\n\n<li>Usar materiales resistentes a la corrosi\u00f3n<\/li>\n<\/ul>\n\n\n\n<p>Las conexiones, especialmente bajo tierra, deben realizarse con m\u00e9todos certificados como soldadura exot\u00e9rmica o conectores avalados.<\/p>\n\n\n\n<p>Esto no es un detalle menor: una mala conexi\u00f3n puede inutilizar todo el sistema.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Equipotencialidad: requisito obligatorio<\/h2>\n\n\n\n<p>Otro aspecto clave es la equipotencialidad. El RETIE exige que todas las partes met\u00e1licas relevantes de una instalaci\u00f3n est\u00e9n conectadas al sistema de tierra.<\/p>\n\n\n\n<p>Esto incluye estructuras, equipos y elementos conductivos. El objetivo es evitar diferencias de potencial peligrosas dentro de la instalaci\u00f3n.<\/p>\n\n\n\n<p>Sin equipotencialidad, incluso un sistema bien dise\u00f1ado puede representar un riesgo.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Accesibilidad y medici\u00f3n<\/h2>\n\n\n\n<p>El dise\u00f1o no termina con la instalaci\u00f3n. El RETIE exige que el sistema sea medible e inspeccionable.<\/p>\n\n\n\n<p>Por eso, se deben incluir puntos accesibles para realizar pruebas, como cajas de inspecci\u00f3n. Esto permite verificar el estado del sistema a lo largo del tiempo y garantizar su funcionamiento continuo.<\/p>\n\n\n\n<p>Aqu\u00ed es donde el dise\u00f1o se conecta con la operaci\u00f3n real del sistema.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Relaci\u00f3n con la resistencia de puesta a tierra<\/h2>\n\n\n\n<p>Aunque el RETIE incluye valores de referencia, deja claro que cumplirlos no es suficiente por s\u00ed solo.<\/p>\n\n\n\n<p>De hecho, el mismo reglamento indica que alcanzar un valor adecuado de <strong>resistencia de puesta a tierra<\/strong> no exime al dise\u00f1ador de garantizar condiciones seguras frente a tensiones de paso y contacto.<\/p>\n\n\n\n<p>Si quieres entender en detalle c\u00f3mo se interpretan estos valores, puedes verlo en este an\u00e1lisis sobre<br><a>valores m\u00e1ximos de resistencia de puesta a tierra<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">El dise\u00f1o como responsabilidad t\u00e9cnica<\/h2>\n\n\n\n<p>El RETIE deja una idea muy clara: el dise\u00f1o no es solo cumplir requisitos, es asumir responsabilidad t\u00e9cnica.<\/p>\n\n\n\n<p>Cada decisi\u00f3n \u2014desde el tipo de electrodo hasta la configuraci\u00f3n del sistema\u2014 debe estar respaldada por criterios de ingenier\u00eda. No se trata de instalar, sino de garantizar que el sistema funcione en condiciones reales.<\/p>\n\n\n\n<p>Para lograrlo, es clave contar con acompa\u00f1amiento especializado y servicios t\u00e9cnicos adecuados, como los que se integran dentro de<br><a href=\"https:\/\/glground.co\/en\/servicios\/?utm_source=chatgpt.com\">servicios de ingenier\u00eda el\u00e9ctrica<\/a> orientados al dise\u00f1o y validaci\u00f3n de estos sistemas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Error com\u00fan: dise\u00f1ar solo para \u201ccumplir\u201d<\/h2>\n\n\n\n<p>Uno de los problemas m\u00e1s frecuentes es dise\u00f1ar \u00fanicamente para cumplir con el RETIE en papel.<\/p>\n\n\n\n<p>Esto lleva a sistemas que pasan inspecciones, pero no necesariamente garantizan seguridad en condiciones reales. El reglamento no busca eso: busca instalaciones que funcionen correctamente frente a fallas el\u00e9ctricas y descargas.<\/p>\n\n\n\n<p>Cumplir la norma no es llenar un requisito, es entenderla y aplicarla correctamente.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusi\u00f3n<\/h2>\n\n\n\n<p>El <strong>RETIE vigente<\/strong> exige que el dise\u00f1o de sistemas de <strong>puesta a tierra<\/strong> sea un proceso t\u00e9cnico completo, basado en medici\u00f3n, c\u00e1lculo y an\u00e1lisis real.<\/p>\n\n\n\n<p>No basta con alcanzar un valor de resistencia. Es necesario:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Analizar el suelo<\/li>\n\n\n\n<li>Evaluar la corriente de falla<\/li>\n\n\n\n<li>Controlar tensiones de paso y contacto<\/li>\n\n\n\n<li>Garantizar continuidad y calidad de materiales<\/li>\n<\/ul>\n\n\n\n<p>Solo cuando todos estos elementos se integran, el sistema cumple realmente su funci\u00f3n: proteger a las personas y a la instalaci\u00f3n.<\/p>\n<\/div>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>El dise\u00f1o de un sistema de puesta a tierra en Colombia no es una decisi\u00f3n t\u00e9cnica aislada, es una obligaci\u00f3n [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"content-type":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3083","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Qu\u00e9 exige el RETIE vigente para dise\u00f1o de sistemas de puesta a tierra en Colombia<\/title>\n<meta name=\"description\" content=\"Descubre los requisitos del RETIE para dise\u00f1ar sistemas de puesta a tierra seguros y conforme a norma en Colombia.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/glground.co\/en\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Qu\u00e9 exige el RETIE vigente para dise\u00f1o de sistemas de puesta a tierra en Colombia\" \/>\n<meta property=\"og:description\" content=\"Descubre los requisitos del RETIE para dise\u00f1ar sistemas de puesta a tierra seguros y conforme a norma en Colombia.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/glground.co\/en\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/\" \/>\n<meta property=\"og:site_name\" content=\"GL\" \/>\n<meta property=\"article:published_time\" content=\"2026-05-14T00:30:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/glground.co\/wp-content\/uploads\/2026\/05\/Gemini_Generated_Image_k5a77lk5a77lk5a7.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1295\" \/>\n\t<meta property=\"og:image:height\" content=\"768\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Gl-User-Web\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Gl-User-Web\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/\"},\"author\":{\"name\":\"Gl-User-Web\",\"@id\":\"https:\/\/glground.co\/#\/schema\/person\/856f3bbe2df0b35ff94a56be3173c7f6\"},\"headline\":\"Qu\u00e9 exige el RETIE vigente para dise\u00f1o de sistemas de puesta a tierra\",\"datePublished\":\"2026-05-14T00:30:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/\"},\"wordCount\":1020,\"publisher\":{\"@id\":\"https:\/\/glground.co\/#organization\"},\"image\":{\"@id\":\"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/glground.co\/wp-content\/uploads\/2026\/05\/Gemini_Generated_Image_k5a77lk5a77lk5a7-1024x607.webp\",\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/\",\"url\":\"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/\",\"name\":\"Qu\u00e9 exige el RETIE vigente para dise\u00f1o de sistemas de puesta a tierra en Colombia\",\"isPartOf\":{\"@id\":\"https:\/\/glground.co\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/glground.co\/wp-content\/uploads\/2026\/05\/Gemini_Generated_Image_k5a77lk5a77lk5a7-1024x607.webp\",\"datePublished\":\"2026-05-14T00:30:00+00:00\",\"description\":\"Descubre los requisitos del RETIE para dise\u00f1ar sistemas de puesta a tierra seguros y conforme a norma en Colombia.\",\"breadcrumb\":{\"@id\":\"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/#primaryimage\",\"url\":\"https:\/\/glground.co\/wp-content\/uploads\/2026\/05\/Gemini_Generated_Image_k5a77lk5a77lk5a7-1024x607.webp\",\"contentUrl\":\"https:\/\/glground.co\/wp-content\/uploads\/2026\/05\/Gemini_Generated_Image_k5a77lk5a77lk5a7-1024x607.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Inicio\",\"item\":\"https:\/\/glground.co\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Qu\u00e9 exige el RETIE vigente para dise\u00f1o de sistemas de puesta a tierra\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/glground.co\/#website\",\"url\":\"https:\/\/glground.co\/\",\"name\":\"GL\",\"description\":\"Soluciones El\u00e9ctricas s.a.s.\",\"publisher\":{\"@id\":\"https:\/\/glground.co\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/glground.co\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/glground.co\/#organization\",\"name\":\"GL\",\"url\":\"https:\/\/glground.co\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/glground.co\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/glground.co\/wp-content\/uploads\/2025\/05\/LogoGLEN.png\",\"contentUrl\":\"https:\/\/glground.co\/wp-content\/uploads\/2025\/05\/LogoGLEN.png\",\"width\":2138,\"height\":839,\"caption\":\"GL\"},\"image\":{\"@id\":\"https:\/\/glground.co\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/glground.co\/#\/schema\/person\/856f3bbe2df0b35ff94a56be3173c7f6\",\"name\":\"Gl-User-Web\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/glground.co\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/3a266f70306defdf189aea9e6ba8832c872409d935ecaf5dcb9fdea31a0d8ef6?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/3a266f70306defdf189aea9e6ba8832c872409d935ecaf5dcb9fdea31a0d8ef6?s=96&d=mm&r=g\",\"caption\":\"Gl-User-Web\"},\"url\":\"https:\/\/glground.co\/en\/author\/gl-user-web\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Qu\u00e9 exige el RETIE vigente para dise\u00f1o de sistemas de puesta a tierra en Colombia","description":"Descubre los requisitos del RETIE para dise\u00f1ar sistemas de puesta a tierra seguros y conforme a norma en Colombia.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/glground.co\/en\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/","og_locale":"en_US","og_type":"article","og_title":"Qu\u00e9 exige el RETIE vigente para dise\u00f1o de sistemas de puesta a tierra en Colombia","og_description":"Descubre los requisitos del RETIE para dise\u00f1ar sistemas de puesta a tierra seguros y conforme a norma en Colombia.","og_url":"https:\/\/glground.co\/en\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/","og_site_name":"GL","article_published_time":"2026-05-14T00:30:00+00:00","og_image":[{"width":1295,"height":768,"url":"https:\/\/glground.co\/wp-content\/uploads\/2026\/05\/Gemini_Generated_Image_k5a77lk5a77lk5a7.webp","type":"image\/webp"}],"author":"Gl-User-Web","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Gl-User-Web","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/#article","isPartOf":{"@id":"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/"},"author":{"name":"Gl-User-Web","@id":"https:\/\/glground.co\/#\/schema\/person\/856f3bbe2df0b35ff94a56be3173c7f6"},"headline":"Qu\u00e9 exige el RETIE vigente para dise\u00f1o de sistemas de puesta a tierra","datePublished":"2026-05-14T00:30:00+00:00","mainEntityOfPage":{"@id":"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/"},"wordCount":1020,"publisher":{"@id":"https:\/\/glground.co\/#organization"},"image":{"@id":"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/#primaryimage"},"thumbnailUrl":"https:\/\/glground.co\/wp-content\/uploads\/2026\/05\/Gemini_Generated_Image_k5a77lk5a77lk5a7-1024x607.webp","inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/","url":"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/","name":"Qu\u00e9 exige el RETIE vigente para dise\u00f1o de sistemas de puesta a tierra en Colombia","isPartOf":{"@id":"https:\/\/glground.co\/#website"},"primaryImageOfPage":{"@id":"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/#primaryimage"},"image":{"@id":"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/#primaryimage"},"thumbnailUrl":"https:\/\/glground.co\/wp-content\/uploads\/2026\/05\/Gemini_Generated_Image_k5a77lk5a77lk5a7-1024x607.webp","datePublished":"2026-05-14T00:30:00+00:00","description":"Descubre los requisitos del RETIE para dise\u00f1ar sistemas de puesta a tierra seguros y conforme a norma en Colombia.","breadcrumb":{"@id":"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/#primaryimage","url":"https:\/\/glground.co\/wp-content\/uploads\/2026\/05\/Gemini_Generated_Image_k5a77lk5a77lk5a7-1024x607.webp","contentUrl":"https:\/\/glground.co\/wp-content\/uploads\/2026\/05\/Gemini_Generated_Image_k5a77lk5a77lk5a7-1024x607.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/glground.co\/que-exige-el-retie-vigente-para-diseno-de-sistemas-de-puesta-a-tierra\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Inicio","item":"https:\/\/glground.co\/"},{"@type":"ListItem","position":2,"name":"Qu\u00e9 exige el RETIE vigente para dise\u00f1o de sistemas de puesta a tierra"}]},{"@type":"WebSite","@id":"https:\/\/glground.co\/#website","url":"https:\/\/glground.co\/","name":"GL","description":"Soluciones El\u00e9ctricas s.a.s.","publisher":{"@id":"https:\/\/glground.co\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/glground.co\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/glground.co\/#organization","name":"GL","url":"https:\/\/glground.co\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/glground.co\/#\/schema\/logo\/image\/","url":"https:\/\/glground.co\/wp-content\/uploads\/2025\/05\/LogoGLEN.png","contentUrl":"https:\/\/glground.co\/wp-content\/uploads\/2025\/05\/LogoGLEN.png","width":2138,"height":839,"caption":"GL"},"image":{"@id":"https:\/\/glground.co\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/glground.co\/#\/schema\/person\/856f3bbe2df0b35ff94a56be3173c7f6","name":"Gl-User-Web","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/glground.co\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/3a266f70306defdf189aea9e6ba8832c872409d935ecaf5dcb9fdea31a0d8ef6?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/3a266f70306defdf189aea9e6ba8832c872409d935ecaf5dcb9fdea31a0d8ef6?s=96&d=mm&r=g","caption":"Gl-User-Web"},"url":"https:\/\/glground.co\/en\/author\/gl-user-web\/"}]}},"_links":{"self":[{"href":"https:\/\/glground.co\/en\/wp-json\/wp\/v2\/posts\/3083","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/glground.co\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/glground.co\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/glground.co\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/glground.co\/en\/wp-json\/wp\/v2\/comments?post=3083"}],"version-history":[{"count":2,"href":"https:\/\/glground.co\/en\/wp-json\/wp\/v2\/posts\/3083\/revisions"}],"predecessor-version":[{"id":3088,"href":"https:\/\/glground.co\/en\/wp-json\/wp\/v2\/posts\/3083\/revisions\/3088"}],"wp:attachment":[{"href":"https:\/\/glground.co\/en\/wp-json\/wp\/v2\/media?parent=3083"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/glground.co\/en\/wp-json\/wp\/v2\/categories?post=3083"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/glground.co\/en\/wp-json\/wp\/v2\/tags?post=3083"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}